Kingspan Access Floors
TORLOCK
PEDESTALS
NATURAL FINISHES
SPEC. CHECKLIST
KINGSPAN WEBSITE

Specification Checklist

Masterspec

Notes

RAISED ACCESS FLOOR
Use this clause where raised access floors are to be specified by proprietary reference.

Heading: This insert should be used to identify intended purpose of the raised access floor i.e. accommodation type. Insert, e.g. in general office area and reception

Drawing references: Consultants’ drawings will be needed to coordinate services, raised access floor support structure and service outlet points at raised access floor level. The more complex the arrangement of services within the void the more critical coordination becomes. A complex installation can involve a whole range of service elements including the following:

Cable trunking
Mains inlet cables running across the subfloor to perimeter distribution points
Air handling units with ducts or plenum distribution
Smoke detectors
Pipe runs for supply, drainage, heating, etc

Manufacturer: Insert, Kingspan Access Floors Ltd

Product reference:
The structural classification should be included in the descriptions if relevant.

Level of access: Insert Full

Floor panel size: The preferred option is 600 x 600mm, but 500 x 500mm and 750 x 750mm are available.

Structural classification: Insert manufacturers structural classification which should relate to a appropriate raised access flooring standard.

Height: Finished raised access floor height above subfloor: Insert the nominal height from the subfloor to the top of the floor panels, including factory bonded finishes where appropriate. The purchaser must specify this.
Under-floor void height. An alternative to the height of the finished floor - this may be more critical.
Limits on maximum and minimum heights: State the design limits if any. Otherwise insert Not applicable.

Other system requirements: Insert, e.g. 600 x 300 mm floor panels adjacent to perimeter air grille. Perimeter air grille and supporting framework as drawing A(57) 12-19.

Specification

RAISED ACCESS FLOOR
Drawing references __________________________________
Manufacturer: Kingspan Access Floors Ltd
- Product reference: ___________________________________

Level of access: Full
Floor panel size: __________________________________mm
Structural classification:________________________________
Installed mass of system (maximum): _________________kg/m2
Height:
- Finished raised access floor height above subfloor: ________mm
- Underfloor void height: ______________________________mm
- Limits on maximum and minimum heights:__________________

Other system requirements: